6013 S

type 
Rutile-cellulosic electrode for stick welding in all positions
applications 
Shipbuilding, general construction, vessels, wagons, repair welding, pipe welding
Properties 

6013S is a medium thick coated electrode for all kinds of steel structures and is particularly suited for welding jobs at poorly accessible points and badly prepared seams. The 6013S can be sued in all positions, in particular it is ideally suited for vertical down welds upto 3,2 mm. Viscous weld metal, hence good gap bridging. Easy slag removal and the electrodes can be bent very well to improve accessibility to hard to reach places.

classification
AWS 
A 5.1: E 6012
EN ISO 
2560-A: E 38 0 RC 11
DIN 
1913: E 51 22RC3
Suitable for 

 

Steel type:
Unalloyed steels:
Boiler plates:
Pipe steels:
-
Shipbilding plates:
Steel castings:
Thin sheets:

DIN:
St 33 to St 52.3
HI, HII, 17 Mn4
St 35 to St 52.4
StE 210.7 to StE 360.7
A, B, D
GS-38 to GS-52
1623/1

W.Nr.:
1.0035 to 1.0570
1.0345, 1.0425, 1.0481
1.0308 to 1.0581
1.0307 to 1.0582
1.0440, 1.0472, 1.0475
1.0416 to 1.0551
-

 

approvals 
TUV (12534.00), CE approved
welding positions: 
Weld deposit weight %

C

Mn

Si

Cr

Ni

Mo

0.08

0.50

0.30

-

-

-

mechanical properties

Heat

RP0,2

Rm

A5

Impact Energy (J) ISO-V

Hardness

Treatment

(N/mm2)

(N/mm2)

(%)

20°C

-40°C

-60°C

HRc / HV

AW

>360

450-550

>22

>60

AW: as welded
redrying temperature 
120°C / 1 hr
welding parameters packing

Welding Parameters

Packing

D (mm)

Length (mm)

Current (A) AC/DC+/-

kg / can

kg / 6pack

kg / 1000

2,0

300

50-60

2.5

15

9.5

2.5

350

65-80

2.5

15

17.6

3.2

350

110-135

2.6

15.6

29

4.0

350

140-170

2.6

15.6

44

5.0

350

180-210

3.4

20.4

66.66

Disclaimer: Whilst all reasonable efforts have been made to ensure the accuracy of the information contained, the information contained or otherwise referenced herein is presented only as “typical” without guarantee or warranty, and any liability incurred from any reliance thereon is expressively disclaimed. Typical data are those obtained when welded and tested in accordance to prescribed standards, and should not be assumed to be the expected results in a particular application or weldment. Other tests and procedures may produce different results. Users are cautioned to confirm by qualification testing, or other appropriate means, the suitability of any welding consumable and procedure before use in the intended application. The selection and use of specific products is solely within the control of, and remains the sole responsibility of the customer. The right to change design and/or specifications without notice is reserved.